Model No.: LE-SOC-24V
Features
Computer Designed Non-directional Smoke Chamber
360° View of Detector Case
Low Profile, 1.8″ Height (with Base)
2 or 4 Wire Base Compatibility, Relay Bases Available
Very Stable Operation, RF/
Standby Current Transient Protection Low, 59μA at 24VDC
Two Built-in Power/Sensitivity Lights for Supervision/Alarm
The automatic sensitivity window check function meets the requirements specified in NFPA 72, Chapters 2 and 7, Inspection, Testing, and Maintenance.
Photoelectric smoke detector
Description
Photoelectric smoke detector
The LE-SOC-24V Photoelectric Smoke Detector uses two dual-color LEDs to indicate status. In the normal standby state, the LEDs flash green every 3 seconds. When the detector senses that its sensitivity has deviated outside the UL listed sensitivity window, the LEDs will flash red every 3 seconds. When the detector senses smoke and goes into an alarm state, the status LEDs will turn red. The detector uses an infrared LED light source and a silicon photo-biode receiving element in the smoke chamber. In the normal standby state, the receiving element receives no light from the pulsed LED light source. In the event of a fire, the smoke enters the detector smoke chamber and the light is reflected from the smoke particles back to the receiving element.
Datasheet
DownloadRelated products
Signal Input Module
Robin fire alarm addressable control panel
1 zone fire alarm control panel
Audible and visual alarm indicator
SensoIRIS MOUT-240
Operating Voltage Range | 15 – 32VDC |
Nominal consumption during communication | 220μA |
Relay Parameters | 4A/ 250VAC; 3A/ 30VDC |
Max. current consumption in STAND-BY mode | 175μA@27VDC |
Wire Gauge for terminals | 0.4mm² – 2.0mm² |
Operating temperature | -10°C to +60°C |
Protection | IP40 |
Weight | ~230g |
Dimensions | 142x80x45 mm |
Repeater TFT IRIS/SIMPO
Power Supply: From the panel External power supply unit | AUX/GND (24±4)VDC |
Maximum power consumption | 0.11A |
Communication | RS 485 |
Twisted pair cable UTP CAT 5: Maximum length between repeater and panel Cross Section | max. 1000m 0.5-2.5mm2 |
Degree of protection | IP40 |
Color, Material | Grey, ABS |
Operation temperature | -5ºС up to +40ºC |
Relative humidity | up to 95% (without condense) |
Storage temperature | -10ºС up to |
Manual Call Point
SensoIRIS T110
Operating Voltage Range | 15-32VDC (Nom. 27VDC) |
Consumption in quiescent state, no communication | < 130μA@27VDC |
Consumption in quiescent state, with communication | < 180μA@27VDC |
Consumption in alarm state, with communication | 6.5mA |
Output in alarm state at terminal RI (terminals 4/ 1) | 7.5 mA (max)/ 7.5V |
Wire Gauge for terminals | 0.4mm² – 2.0mm² |
Operating temperature | -10°C to +65°C |
Protection | IP30 |
Weight (including base) | ~110g |
Dimensions (including base) | 103x42mm |