Fire Hydrants
Fire Hydrants
SFFECO sees hydrants as a critical fire fighting product, which needs to serve its purpose without fail. Designed built and tested for dependability.
SFFECO fire hydrants are generally made in cast iron and in ductile iron too as per customer’s demand. SFFECO Fire Hydrants are used in commercial centers, colleges, hospitals, shopping malls, etc.
SFFECO Fire Hydrants, which are designed to be weatherproof, are normally equipped with hoses, hose nozzles, hydrant wrenches, spanner wrenches, fie axes, and flashing light, torch, etc as per customer’s requirements.
- SFFECO has UL/FM Dry barrel fire hydrant model SF-F-06 provides smooth and optimum performance with highest quality.
- SFFECO Wet Barrel Fire Hydrant model SFD-250-WH is UL/FM approved.
- SFFECO has LPCB approved models of Dry Pillar Fire Hydrants.
Categories: Fire Hydrants, SFFECO
Description
Related products
Portable dry powder fire extinguishers
Model | PD1 | PD2 | PD6 | PD10 | PD12 | PDB5 | PDB10 |
---|---|---|---|---|---|---|---|
Capacity | 1 Kg | 2 Kg | 6 Kg | 10 Kg | 12 Kg | 5 Lbs | 10 Lbs |
Effective Range | 4 m | 4 m | 6.5 m | 8.5 m | 8.5 m | 4 m | 5.5 m |
Discharge Duration | 6-10 Sec | 6-10 Sec | 10-14 Sec | 14-22 Sec | 14-22 Sec | 6-10 Sec | 8-11 Sec |
Working Pressure | 12-15 bar | 12-15 bar | 12-15 bar | 12-15 bar | 12-15 bar | 12-15 bar | 12-15 |
EJ Type – Standard Pumps
EDJ Type Models
Flow (GPM) | Skid Width (mm) | Skid Height (mm) | Skid Length (mm) | Motor (HP) | Jockey (HP/GPM) | Header Pipe |
---|---|---|---|---|---|---|
50 | 700 | 1230 | 830 | 5.5 | 3 / 10 | 1.5" |
120 / 150 | 800 | 1250 | 1220 | 15 | 3 / 10 | 2" |
250 / 300 | 800 | 1420 | 1220 | 30 | 3 / 15 | 4" |
500 | 900 | 1660 | 1350 | 5.5 | 5.5 / 25 |
Fire Hose Reels & Accessories
model | measuring | classification |
---|---|---|
SH19R | 19 mm | Type A, Class 2 |
SH25R | 25 mm | Type A, Class 2 |
Fire hose reels are designed and manufactured in accordance with BS EN671 – 1. Hose reel discs are made of 1.2 mm electro-galvanized steel sheet pre-treated and coated with electrostatic powder coating and oven baked at 200°C. The side panels of the hose reel are protected with a polyester powder coating which meets the salt spray test requirements specified in ISO 9227 for 240 hours.
The hose reel drum features a configuration of hydraulically compressed ribs to give extra strength and avoid twisting. The outer edges are turned to give a secure edge treatment on the outer rims and a better look.
Automatic Fire Hose Reels are available with an internal valve built into the hose reel unit which opens during 3 turns of the hose reel as the hose is pulled out and closes when the hose is wound back onto the reel.
SFFECO Fire Hose Angle Valves (90° Pattern) are used on vertical pipes that have the inlet and outlet the same size or with the inlet larger than the outlet. The valve is manufactured according to UL668 hose valve for fire protection service standards.
SFFECO UL Listed single and double fire hoses are lined with high-tech EPDM tube whose engineered design ensures minimal weight with maximum durability and flexibility.
SFFECO UL Type Adjustable Nozzles are used on Class A and Class B fires in most industrial applications. They are used with a lined fire hose.
model | manual | automatic |
---|---|---|
static type | SF 30 F-19 SF 30 F-25 | sf 30 AF-19 sf 30 AF-25 |
Swing tube type | SF 30 SP-19 SF 30 SP-25 | SF 30 A-SP-19 SF 30 A-SP-25 |
swing arm type | SF 30 SA-19 SF 30 SA-25 | SF 30 A-SA-19 SF 30 A-SA-25 |
Fire Hose Cabinet SFR150, SFR200
Fire doors and frames
Fire doors and frames
As part of our continuous pursuit of innovation, SFFECO has launched its world-class fire rated doors and frames. The fire doors and frames are manufactured in a fully automated factory using CNC machines thus ensuring uniform quality and a great finish. SFFECO fire doors are manufactured to comply with various architectural requirements. These doors are designed for areas where strength, stability and durability are priorities. Typical applications include industrial building entrances, shop service doors, basement floors, stairwells, and elevator shafts. It is also widely used as partition or exterior doors in electrical and petrochemical plants. The door or frame can be made of cold rolled steel, galvanized steel or stainless steel. Doors can be used in drywall and masonry construction.Mobile Foam Fire Extinguishers
Model | TF25 | TF10G | TF50 | TF100 | TF35G | TFC50 | TFC100 | TFC35G |
---|---|---|---|---|---|---|---|---|
Capacity (L) | 25 | 37.8 | 50 | 100 | 132 | 50 | 100 | 132 |
Effective Range | 8 m | 8 m | 8 m | 8 m | 8 m | 8 m | 8 m | 8 m |
Discharge Duration | 19-23 Sec | 29-33 Sec | 38-42 Sec | 77-82 Sec | 100-105 Sec | 42-45 Sec | 82-85 Sec | 110-120 Sec |
Working Pressure | 12-15 bar | 12-15 bar | 12-15 bar | 12-15 bar | 12-15 bar | 12-15 bar | 12-15 bar | 12-15 bar |