Fire Pump Controllers
Description
All Fire Pump Controllers are factory assembled, wired, and comply to all requirements of the latest edition of NFPA-20 (Centrifugal Fire Pumps) and NFPA-70 (National Electrical Code). All controllers are Y2K compliant.
Attachment
Related products
Photoelectric smoke detector
Model No.: LE-SOC-24V
Features
Computer Designed Non-directional Smoke Chamber
360° View of Detector Case
Low Profile, 1.8" Height (with Base)
2 or 4 Wire Base Compatibility, Relay Bases Available
Very Stable Operation, RF/
Standby Current Transient Protection Low, 59μA at 24VDC
Two Built-in Power/Sensitivity Lights for Supervision/Alarm
The automatic sensitivity window check function meets the requirements specified in NFPA 72, Chapters 2 and 7, Inspection, Testing, and Maintenance.
Vertical Turbine Fire Pump
Features
- Capacity: 200 GPM – 2000 GPM
- Pressures: 40 – 355 psi
- Maximum Working Pressures: 290 to 395 PSI
- Speed: 1480,1760, 2900,2980, 3000 RPM
- Dynamically Balanced Impeller extends bearing life and ensures smoother operation.
- Designed and built as per UL 448 AND NFPA20 for maximum reliability.
- Constructed in variety of metallurgies.
- Available in 50 Hz and 60 Hz.
- Drivers with gear boxes at electric and diesel speeds.
- Designed for easy maintenance without interfering with piping.
- Open line shaft, water lubricated construction for ease of maintenance.
- Self-Venting Design eliminates vapor lock and the need for automatic air release valve
4 zone fire alarm control panel
Centrifugal End Suction Fire Pumps
Model No. | Rated Capacity (GPM) | Size(SucXDis) (inches) | UL Listed Rated Net Pressure Range (PSI) | FM Approved Rated Net Pressure Range (PSI) | SETSCO & CE Pressure(PSI) | Approx Speed (RPM) | Max Working Pressure (PSI) |
---|---|---|---|---|---|---|---|
SFP-50-20 EM-2G | 50 | 2 ½ X 2 | 74 - 93 | 74 - 93 | 74 - 93 | 2900 | 180 |
SFP-50-20 EM-2G | 50 | 2 ½ X 2 | 79 - 99 | 79 - 99 | 79 - 99 | 3000 | 180 |
SFP 50-20 EM | 50 | 2 x 1 ¼ | 68 - 87 | 68 - 88 | 68 - 87 | 2900 | 230 |
SFP 50-20 EH | 50 | 2 x 1 ¼ | 101 -129 | 102 - 129 | 101 -129 | 3500 | 230 |
SFP 50-26 EM | 50 | 2 x 1 ¼ | 115 -140 | 115 - 133 | 115 -140 |
DJ Type – Standard Pumps
Flow (GPM) | Skid Width (mm) | Skid Height (mm) | Skid Length (mm) | Diesel Engine (HP) | Jockey (HP/GPM) | Header Pipe |
---|---|---|---|---|---|---|
50 | 700 | 1230 | 830 | 10 | 3 / 10 | 1.5" |
120 / 150 | 800 | 1280 | 1220 | 25 | 3 / 10 | 2" |
250 / 300 | 800 | 1420 | 1220 | 25 | 3 / 15 | 4" |
500 | 1000 | 1670 | 1600 | 60 | 5.5 / 25 | 6" |
750 | 1100 | 1760 | 1700 | 85 | 5.5 / 35 |
EDJ Type – Standard Pumps
Flow (GPM) | Skid Width (mm) | Skid Height (mm) | Skid Length (mm) | Diesel Engine (HP) | Motor (HP) | Jockey (HP/GPM) | Header Pipe |
---|---|---|---|---|---|---|---|
50 | 650 | 1250 | 1230 | 8 | 5.5 | 3 / 10 | 2" |
120 / 150 | 1220 | 1300 | 1220 | 15 | 15 | 3 / 10 | 2.5" |
250 / 300 | 1220 | 1420 | 1220 | 25 | 30 | 3 / 15 | 4" |
350 | 1550 | 1630 | 1600 | 40 | 40 | 3 / 20 | 4" |
500 | 1600 | 1420 | 1800 | 60 | 50 | 5.5 / 25 | 6" |
750 | 1700 | 1300 | 1800 | 85 | 75 | 5.5 / 35 | 6" |
1000 | 1700 | 1250 | 2000 | 100 | 100 |