Showing 1–12 of 21 results

Caprari K-KOMPACT

Dry installed sewage electric pumps.
Flow rate up to l/s 750
Head up to m 65
Power up to kW 200

Caprari K+ DN 100

Electric submersible pumps DN 100 - 250.
Flow rate up to l/s 300
Head up to m 66
Power up to kW 32

Caprari K+ DN 65

Electric submersible pumps DN 65 - 200.
Flow rate up to l/s 160
Head up to m 65
Power up to kW 15

Caprari MEC A

Horizontal centrifugal single stage pumps.
Flow rate up to l/s 130
Head up to m 140
Power up to kW 132

Caprari P6 – P18 Series

Vertical turbine pumps

Flow rate up to l/s 400
Head up to m 250
Power up to kW 400
Efficiency above 84%

Centrifugal End Suction Fire Pumps

Model No. Rated Capacity (GPM) Size(SucXDis) (inches) UL Listed Rated Net Pressure Range (PSI) FM Approved Rated Net Pressure Range (PSI) SETSCO & CE Pressure(PSI) Approx Speed (RPM) Max Working Pressure (PSI)
SFP-50-20 EM-2G 50 2 ½ X 2 74 - 93 74 - 93 74 - 93 2900 180
SFP-50-20 EM-2G 50 2 ½ X 2 79 - 99 79 - 99 79 - 99 3000 180
SFP 50-20 EM 50 2 x 1 ¼ 68 - 87 68 - 88 68 - 87 2900 230
SFP 50-20 EH 50 2 x 1 ¼ 101 -129 102 - 129 101 -129 3500 230
SFP 50-26 EM 50 2 x 1 ¼ 115 -140 115 - 133 115 -140

Centrifugal Horizontal Split Case Fire Pumps

NOTE:
  1. All Pumps are Hydrostatically Tested to minimum of 150% of its Maximum Working Pressure and can withstand Double the Max.Working Pressure.
  2. All Pumps have Clock-Wise Rotation when viewed from the Driver Side.
  3. All Pumps are horizontal single stage Pumps.
  4. “The rated speed marked on the pump can vary within +/-4% of the listed/ approved rated speed example: 3000 RPM pump can be driven with 2900 RPM Drivers.”
Model No. Rated Capacity (GPM) Size (SucXDis) UL Listed Rated Net Pressure Range (PSI) FM Approved Rated Net Pressure Range (PSI) SETSCO & CE Rated Net Pressure Range (PSI) Approx Speed (RPM) Max Working Pressure (PSI)
SFP150-25SH 150 6 x 4 114-208 114-208 114-208 3500 300
SFP150-25SH 150 6 x 4 121-220 121-220 121-220 3600 300
SFP150-40SM 150 6 x 4 206-289 206-289 206-289 2900 385
SFP150-40SM 150 6 x 4 221-310 221-310 221-310 3000 385
SFP150-SN31SH 150 6 x 4 226-316 226-316 226-316

Centrifugal Vertical Turbine Fire Pumps

NOTE:
  1. All Pumps are Hydrostatically Tested to minimum of 150% of its Maximum Working Pressure and can withstand Double the Max.Working Pressure.
  2. All Pumps have Clock-Wise Rotation when viewed from the Driver Side.
  3. All Pumps are Multistage with 2 stages as minimum requirement.
  4. “The rated speed marked on the pump can vary within +/-4% of the listed/ approved rated speed example: 3000 RPM pump can be driven with 2900 RPM Drivers.”
 
Model No. Capacity (GPM) UL,SETSCO & CE Listed Net Pressure (PSI) Number of Stages FM Approved Rated Net Pressure (PSI) Number of Stages Approx Speed (RPM)
SFP-200-70VT 200 40 - 248 2 - 12 40 - 289 2 - 12 1480
SFP-200-70VT 200 48 - 348 2 - 10 64 - 348 2 - 10 1480
SFP-200-30VT 200 60 - 305 2 - 6 2900
SFP-200-30VT 200 63 - 323 2 - 6 2980
SFP-200-30VT 200 64 - 327 2 - 6 3000

Diesel Driven Skids

LIFECO Diesel Driven Centrifugal Fire Pump Skids are available in combinations of both Listed and Approved Centrifugal End Suction Pumps and Centrifugal Horizontal Split Case Pumps coupled with Listed Diesel Engine Drivers

Diesel Tanks

All LIFECO Steel Above ground Tanks for flammable and combustible Liquid are assembled and tested to all requirements as follows * ANSI/UL-142 – Compliant. * Installation standard compliance to NFPA 30, NFPA 30A and NFPA 31 * Primary and Secondary containment

DJ Type – Standard Pumps

The below shown models are our standard models.Other combinations & configurations are available on request and can be designed as per customer or project requirements.
Flow (GPM) Skid Width (mm) Skid Height (mm) Skid Length (mm) Diesel Engine (HP) Jockey (HP/GPM) Header Pipe
50 700 1230 830 10 3 / 10 1.5"
120 / 150 800 1280 1220 25 3 / 10 2"
250 / 300 800 1420 1220 25 3 / 15 4"
500 1000 1670 1600 60 5.5 / 25 6"
750 1100 1760 1700 85 5.5 / 35

EDJ Type – Standard Pumps

Other combinations & configurations are available on request and can be designed as per customer or project requirements.
Flow (GPM) Skid Width (mm) Skid Height (mm) Skid Length (mm) Diesel Engine (HP) Motor (HP) Jockey (HP/GPM) Header Pipe
50 650 1250 1230 8 5.5 3 / 10 2"
120 / 150 1220 1300 1220 15 15 3 / 10 2.5"
250 / 300 1220 1420 1220 25 30 3 / 15 4"
350 1550 1630 1600 40 40 3 / 20 4"
500 1600 1420 1800 60 50 5.5 / 25 6"
750 1700 1300 1800 85 75 5.5 / 35 6"
1000 1700 1250 2000 100 100