Electric Driven Skids
Features
- Driven by UL Listed Electric Motor.
- Well aligned and Coupled for Direct Operation.
- Skid Packages are Pre-Tested and Inspected thoroughly before release to customers.
- Engineered, coated, hot rolled mild steel to resist corrosion and abrasion.
- Compact skid Design with Small Foot-Print for Retrofit.
- High standard of Quality in material Construction finish and Workmanship
Attachment
Related products
Gas extinguishing panel
Model Number: LF/EX
Attributes
Solid steel powder-coated cabinet
Built-in battery and internal charger
System status indicator
Charge & error indicators. Battery failure
Alarm circuits monitored for both open and short circuit
Manual trigger switch on front
2 monitored detection zones
Gas release
knockout monitored on top and bottom sides for easy installation
Communication relay
Control switch Release
timer
Caprari MEC A
Centrifugal Horizontal Split Case Fire Pumps
- All Pumps are Hydrostatically Tested to minimum of 150% of its Maximum Working Pressure and can withstand Double the Max.Working Pressure.
- All Pumps have Clock-Wise Rotation when viewed from the Driver Side.
- All Pumps are horizontal single stage Pumps.
- “The rated speed marked on the pump can vary within +/-4% of the listed/ approved rated speed example: 3000 RPM pump can be driven with 2900 RPM Drivers.”
Model No. | Rated Capacity (GPM) | Size (SucXDis) | UL Listed Rated Net Pressure Range (PSI) | FM Approved Rated Net Pressure Range (PSI) | SETSCO & CE Rated Net Pressure Range (PSI) | Approx Speed (RPM) | Max Working Pressure (PSI) |
---|---|---|---|---|---|---|---|
SFP150-25SH | 150 | 6 x 4 | 114-208 | 114-208 | 114-208 | 3500 | 300 |
SFP150-25SH | 150 | 6 x 4 | 121-220 | 121-220 | 121-220 | 3600 | 300 |
SFP150-40SM | 150 | 6 x 4 | 206-289 | 206-289 | 206-289 | 2900 | 385 |
SFP150-40SM | 150 | 6 x 4 | 221-310 | 221-310 | 221-310 | 3000 | 385 |
SFP150-SN31SH | 150 | 6 x 4 | 226-316 | 226-316 | 226-316 |
Battery operated smoke detector
Model Number: LF-SD41
Attributes
Photoelectric technology is more sensitive in detecting large particle fires
Perfect mounting system allows for easy installation and positioning
Dust cover included to keep the alarm clean during construction
9V backup battery included
One button test/silence
Smart technology designed to help reduce Unwanted nuisance alarms
Easy installation/maintenance
Centrifugal End Suction Fire Pumps
Model No. | Rated Capacity (GPM) | Size(SucXDis) (inches) | UL Listed Rated Net Pressure Range (PSI) | FM Approved Rated Net Pressure Range (PSI) | SETSCO & CE Pressure(PSI) | Approx Speed (RPM) | Max Working Pressure (PSI) |
---|---|---|---|---|---|---|---|
SFP-50-20 EM-2G | 50 | 2 ½ X 2 | 74 - 93 | 74 - 93 | 74 - 93 | 2900 | 180 |
SFP-50-20 EM-2G | 50 | 2 ½ X 2 | 79 - 99 | 79 - 99 | 79 - 99 | 3000 | 180 |
SFP 50-20 EM | 50 | 2 x 1 ¼ | 68 - 87 | 68 - 88 | 68 - 87 | 2900 | 230 |
SFP 50-20 EH | 50 | 2 x 1 ¼ | 101 -129 | 102 - 129 | 101 -129 | 3500 | 230 |
SFP 50-26 EM | 50 | 2 x 1 ¼ | 115 -140 | 115 - 133 | 115 -140 |
Matrix Network Vision Anchor
Matrix Network Vision Anchor
The large, full-color graphic display with touch screen functionality provides fire alarm system status information to single or multiple locations. Matrix Vision Annunciator can be configured to provide full display and control to replicate fire control panel functionality or to act as a simple display device for applications where access to fire alarm system control is inconvenient.
Battery operated heat detector
Photoelectric smoke detector
Model No.: LE-SOC-24V
Features
Computer Designed Non-directional Smoke Chamber
360° View of Detector Case
Low Profile, 1.8" Height (with Base)
2 or 4 Wire Base Compatibility, Relay Bases Available
Very Stable Operation, RF/
Standby Current Transient Protection Low, 59μA at 24VDC
Two Built-in Power/Sensitivity Lights for Supervision/Alarm
The automatic sensitivity window check function meets the requirements specified in NFPA 72, Chapters 2 and 7, Inspection, Testing, and Maintenance.