Flanged X Grooved – 300 PSI
- Complies with AWWA C515 Standard
- NPT plug on body
- 300PSI Working pressure
- -10°C to 82°C Working temperature
- Ductile Iron Body
- Sizes: 2.5”, 3” – UL Listed
- Sizes: 2.5”, 3”, 4”, 5”, 6”, 8”, 10” & 12” – FM Approved
Categories: LIFECO, NRS Type Gate Valves, Valves
Attachment
Related products
Signal Input Module
4 zone fire alarm control panel
Horizontal Sidewall Sprinkler
Temperature Fire Alarm Detector
Application
The F10 is suitable for environments, where sudden large temperature changes are considered as normal, rooms with high concentration of vaporous, exhaust gases, dust, etc. For example: kitchens, garages, boiler rooms or other places where it is not convenient to install fire alarm optical smoke detectors.Conventional Fire Alarm Bell
Manual Call Point
Operating voltage 9 ÷ 30 VDC
Nominal operating
voltage 24 VDC
Current consumption in
alarm state
23mA/15V; 38mA/24V;
48mA/30V
Installation wires 0,4mm2 ÷ 2.0mm2
Operation temperature -10°C ÷ +60°C
Relative humidity ≤93% @ +40°C
Type of the frangible
element A
Material (plastic), Color ABS, red
Degree of protection IP40
Dimensions (incl. base) 90x57x90mm
Battery operated smoke detector
Model Number: LF-SD41
Attributes
Photoelectric technology is more sensitive in detecting large particle fires
Perfect mounting system allows for easy installation and positioning
Dust cover included to keep the alarm clean during construction
9V backup battery included
One button test/silence
Smart technology designed to help reduce Unwanted nuisance alarms
Easy installation/maintenance
End suction fire pump
LIFECO pumps undergo the required inspection, tests and production control during the assembly process and records are kept for the same, before they are delivered to our customers. Each pump is produced, and subjected to performance tests as follows:
a) Test run
performance curves plotted showing efficiency, brake force (kW), and total head developed at shutdown, at rated capacity, at 150 percent of rated capacity, And at selected intermediate capacities between closing and maximum capacities exceeding 150% of the rated capacity.
b) Hydrostatic Test
Each pump shall be hydrostatically tested for a minimum of 5 minutes. The test pressure shall be up to two times
the maximum working pressure of the pump, but in no case less than 250 psi (1724 kPa) to ensure that there is no
rupture or leakage through the castings at the test pressure.
c) Motor Balance
The impellers of each pump are dynamically balanced with a balance quality grade of G6.3 accordingly
with the requirements for the pumps impellers in the Mechanical Vibration Standard – Balance Quality